3nh New Horizontal Type Color Haze Meter

July 2, 2021
Latest company news about 3nh New Horizontal Type Color Haze Meter

3nh New Horizontal Type Haze Meter

latest company news about 3nh New Horizontal Type Color Haze Meter  0

3nh New Horizontal Type Haze Meter

latest company news about 3nh New Horizontal Type Color Haze Meter  0

Product model YH1810 Color Haze Meter YH1800 Color Haze Meter YH1210 Haze Meter
Geometry Transmittance: 0/D (parallel illumination, diffuse receiving); Conform to the standards: ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410, JJF 1303-2011,CIE 15.2,GB/T 3978,ASTM E308,JIS K7105,JIS K7361,JIS K 7136 Transmittance: 0/D (parallel illumination, diffuse receiving); Conform to the standards: ASTM D1003/1044, ISO 13468,ISO 14782,GB/T 2410, JJF 1303-2011,CIE 15.2,GB/T 3978, ASTM E308,JIS K7105,JIS K7361,JIS K 7136 Transmittance: 0/D (parallel illumination, diffuse receiving) in accordance with standards: ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136
Characteristic The instrument can easily realize ASTM D1003 non-compensated method, ISO 13468 compensation method, Full transmittance, haze test, Clarity test. The instrument can accurately collect the transmittance curve of the transmitted sample, and can accurately output various chroma data of the transmitted sample. High hardware configuration, open measurement area, vertical, horizontal testing. It is widely used in glass processing, plastic processing, film, display screen processing, packaging industry, liquid analysis and other aspects. The instrument can easily realize ASTM D1003 non-compensated method, ISO 13468 compensation method, Full transmittance, haze test. The instrument can accurately collect the transmittance curve of the transmitted sample, and can accurately output various chroma data of the transmitted sample. High hardware configuration, open measurement area, vertical, horizontal testing. It is widely used in glass processing, plastic processing, film, display screen processing, packaging industry, liquid analysis and other aspects. The instrument can easily realize ASTM D1003 uncompensated method, ISO 13468 compensation method, Full transmittance, haze test. Open measurement area for vertical and horizontal testing. It is widely used in glass processing, plastic processing, film, display screen processing, packaging industry, liquid analysis and other aspects.
Integrating sphere size Φ 154 mm Φ 154 mm Φ 154 mm
Light source 400 ~ 700 nm combined LED light source (wavelength extended is customized) 400 ~ 700 nm combined LED light source (wavelength extended is customized) 400 ~ 700 nm combined LED light source
Spectrophotometric Mode Concave grating Concave grating /
Sensor 256 pixel dual array CMOS image sensor 256 pixel dual array CMOS image sensor PD array detector, satisfying CIE V(λ)2 degree visual response
Wavelength range 400 ~ 700 nm (wavelength scalable customization) 400 ~ 700 nm (wavelength scalable customization) /
Wavelength interval 10 nm 10 nm /
Half bandwidth 10 nm 10 nm /
Measurement Range 0-100% 0-100% 0-100%
Measuring aperture Φ20 mm/Φ15 mm/Φ8 mm/Φ4 mm (select single aperture) Φ20 mm/Φ15 mm/Φ8 mm/Φ4 mm (select single aperture) Φ20 mm/Φ15 mm/Φ8 mm/Φ4 mm (select single aperture)
Sample size Thickness less than 105 mm Thickness less than 105 mm Thickness less than 105 mm
Color space CIE LAB,XYZ,Yxy,LCh,s-RGB,βxy CIE LAB,XYZ,Yxy,LCh,s-RGB,βxy /
Chromatic formula ΔE*ab,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00 ΔE*ab,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00 /
Other chromaticity index Haze (ASTM D1003/1044, ISO 13468), Transmittance T (ISO), Transmittance T (ASTM), Clarity test, WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), Absorbance, Cobalt Platinum Index, Gardner Index Haze (ASTM D1003/1044, ISO 13468), Transmittance T (ISO), Transmittance T (ASTM), WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), Absorbance, Cobalt Platinum Index, Gardner Index Haze (ASTM D1003/1044, ISO 13468), Transmittance T (ISO), Transmittance T (ASTM),
Observer angle 2 °/10 ° 2 °/10 ° 2 °
Light source D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 D65,A,C
Display Data Spectrogram, sample chroma value, color difference/graph, color graph, color simulation, pass/fail result Spectrogram, sample chroma value, color difference/graph, color graph, color simulation, pass/fail result Pass/fail result
Measurement time About 1.5s About 1.5s About 1.5s
Resolution 0.01 unit 0.01 unit 0.01 unit
Repeatability Φ20 mm aperture, less than 0.08 (after instrument preheating and correction, test the standard nebulizer with the nebulization of about 40 at an interval of 5s for 30 times of standard deviation) Φ20 mm aperture, less than 0.08 (after instrument preheating and correction, test the standard nebulizer with the nebulization of about 40 at an interval of 5s for 30 times of standard deviation) Φ20 mm aperture, less than 0.1 (after instrument preheating and correction, test the standard nebulizer with the nebulization of about 40 at an interval of 5s for 30 times of standard deviation)
Inter-instrument Error Φ20 mm aperture, less than 0.4 (after instrument preheating and correction, test the standard deviation between the standard nebulizer of nebulization and the reference value at an interval of 5s) Φ20 mm aperture, less than 0.4 (after instrument preheating and correction, test the standard deviation between the standard nebulizer of nebulization and the reference value at an interval of 5s) Φ20 mm aperture, less than 0.4 (after instrument preheating and correction, test the standard deviation between the standard nebulizer of nebulization and the reference value at an interval of 5s)
Dimensions Length X Width X Height = 487X260X298mm Length X Width X Height = 487X260X298mm Length X Width X Height = 487X260X298mm
Weight Approx. 8.0 kg Approx. 8.0 kg Approx. 8.0 kg
Power supply 24V 3A , DCpower adapter 24V 3A , DCpower adapter 24V 3A , DCpower adapter
Illuminant Life Span > 3 million measurements in 5 years > 3 million measurements in 5 years > 3 million measurements in 5 years
Display TFT True Color 7 inch, Capacitive Touchscreen TFT True Color 7 inch, Capacitive Touchscreen TFT True Color 7 inch, Capacitive Touchscreen
Interface USB, Print Serial, Bluetooth USB, Print Serial, Bluetooth USB, Print Serial
Data Storage 5,000 samples, 30,000 samples 5,000 samples, 20,000 samples 1,000 samples, 20,000 samples
Language Simplified Chinese, Traditional Chinese, English Simplified Chinese, Traditional Chinese, English Simplified Chinese, Traditional Chinese, English
Operating Temperature 0 to 40 ° C (32 to 104 ° F) 0 to 40 ° C (32 to 104 ° F) 0 to 40 ° C (32 to 104 ° F)
Storage Temperature - 20 – 50 ° C (-4 – 122 ° F) - 20 – 50 ° C (-4 – 122 ° F) - 20 – 50 ° C (-4 – 122 ° F)
Standard Accessories Power adapter, user manual, quality management software (download), USB cable, 0% calibration box, measuring aperture Power adapter, user manual, quality management software (download), USB cable, 0% calibration box, measuring aperture Power adapter, user manual, quality management software (download), USB cable, 0% calibration box, measuring aperture
Optional Accessories Micro printer, Test Fixture, Standard haze sheet, Footswitch Micro printer, Test Fixture, Standard haze sheet, Footswitch Micro printer, Test Fixture, Standard haze sheet, Footswitch
Notes: Subject to change without notice Subject to change without notice Subject to change without notice