Home News

Why did NR110 colorimeter color comparisons chang a lot indoor and outdoor?

Certification
Good quality Colour Measurement Spectrophotometer for sales
Good quality Colour Measurement Spectrophotometer for sales
Customer Reviews
The product and the service was excelent. it came to colombia without many problems (just aduana problems)..supplier 100% recomenmed

—— Eider Granada

Everything was delivered in perfect condition. After assembly, I confirmed operation. Thank you for this product.

—— Josiah Hall

Everything went as expected and the product arrived in good condition. 3NH is a good supplier and I will definitely use them in the future.

—— Mihai Paunescu

T60 (5) color Light Box - 600 mm -5 lights It seems the same like the image

—— Penney Ubieta

good performance and will buy another one soon.

—— Stuart Serchuk

Medidor de brillo es hermoso

—— Mauritius Telecom

I got model HG60 gloss meter. it is good to test the gloss on our metal product after powder coating. thanks a lot

—— Cliff Lai

Standard Color Viewer Transmission Light Box, Type: HC5100/HC3100 I got this light box, and it worked very well like DNP light box. I will use it for our transparent test charts often.

—— Klaus Kohl

Good morning^^ Thank you for your product. Thank you for sending me a good product. Have a great day today.

—— Kim Hee-jung

We have received the machine in good condition.(NR110 , T60(4))

—— Woot Usanachitt

The 2 equipment NS810 spectrophotometer and T60+ light box works fine. I will contact you when i need assistance.

—— Patrick Unifine

Thank you for your email and the superb service you provide for model NR145 COLORIMETER. Everything is working fine, like expected. For now we do not need a gloss meter. But, I will keep it in mind for future experiments and recommend you to other collegues.

—— Kristof Holsteens

hi Melorae it is working fine. thank you regards Chia

—— Chia

We have got YS3060 spectrometer and it works fine

—— Ruslanas Fadiuškinas

We are trying the colorimeter NR110 and the results are so good at the moment. Now, we are looking for another colorimeter with 45º method. We would like this colorimeter is portable and as complete as you can because it will be for lab trials.

—— Judith Sánchez

Hi Melorae Sure, everything is fine, we are preparing a good test environment for production to check the quality of the assembled products. The chart is fundamental!

—— Max Massimiliano Marchionni

I'm Online Chat Now
Company News

Why did NR110 colorimeter color comparisons chang a lot indoor and outdoor?

Why did NR110 colorimeter color comparisons chang a lot indoor and outdoor?
Why did NR110 colorimeter color comparisons chang a lot indoor and outdoor?
 
Questions:
 
Because the customer Make color comparisons. The customer said that the device changed very high.The model used to measure is the model NR110 colorimeter. Indoor temple customer Same color sheet And outdoor temples.Without moving any position Sample image Error to 5-30 Delta E. Customers say the device is not good. I am very stressed and worried.
 
Why NR110 colorimeter color comparisons changed a lot indoor and outdoor
Why NR110 colorimeter color comparisons changed a lot indoor and outdoor
 

Answers:

Because the corresponding wavelength range of 3nh NR110 colorimeter detectors is very wide, ranging from 360 to 1300 nm, while the light source wavelength range of the instrument is 400 to 700 nm, and there are filters in front of the detector. The filtering range of the filters is only 400 to 700 nm. If there is additional light source interference and the wavelength range is 700 to 1300 nm or 360 to 400 nm, the instrument can not identify these interference, so it will be big deviations.

Processing method: Measure in the office environment or laboratory environment. The wavelength range of office lighting environment is generally within 400-700 nm. If we can test in darkroom environment, the effect will be better.

If it is necessary to test outdoors, black-and-white board calibration should be done in the same outdoor environment to keep the environmental noise and temperature consistent, so that the error can be minimized.

The test environment is very important: to ensure two points, calibration and test sample temperature and background light as consistent as possible.

If the data of indoor test is to be compared with that of outdoor test, it is better to do black-and-white correction againfor NR110 colorimeter during outdoor test, and then transfer the data of indoor test as standard sample.

Pub Time : 2019-04-28 10:57:03 >> News list
Contact Details
Shenzhen ThreeNH Technology Co., Ltd.

Contact Person: Mrs. Melorae

Tel: 86-755-2719-8826

Fax: 86-755-2719-0609

Send your inquiry directly to us (0 / 3000)