3nh Spectrophotometer
-
Color Spectrophotometer
-
Colour Measurement Spectrophotometer
-
Handheld Color Spectrophotometer
-
Light Box Color Assessment Cabinet
-
Haze Meter
-
Digital Gloss Meter
-
Multi Angle Gloss Meter
-
3nh Colorimeter
-
Color Difference Meter
-
Color Matching Machine
-
Color Matching Software
-
Resolution Test Chart
-
Colour Shade Card
-
Paint Color Cards
-
Fluorescent Tube Light
-
Spectrophotometer Accessories
-
Eider GranadaThe product and the service was excelent. it came to colombia without many problems (just aduana problems)..supplier 100% recomenmed
-
Josiah HallEverything was delivered in perfect condition. After assembly, I confirmed operation. Thank you for this product.
-
Mihai PaunescuEverything went as expected and the product arrived in good condition. 3NH is a good supplier and I will definitely use them in the future.
Portable 3nh Spectrophotometer , TS7700 Plastic Color Matching Machine With Munsell Color Space

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xOptical Geometry | D/8° | SCE/SCI | SCE & SCI |
---|---|---|---|
UV Light Source | Yes | Repeatibility | ΔE*≤0.02 |
Inter-instrument Agreement | ΔE*≤0.15 | Measuring Aperture | 8mm & 4mm |
High Light | hunter lab spectrophotometer,color measurement instruments |
Plastic color matching machine portable spectrophotometer 3nh TS7700 with Munsell color space to replace CM2600D
Specification:
Model | TS7700 |
Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) |
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source | |
Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 | |
Characteristic | double apertures for accurate color analysis and transmission in laboratory |
It is used for precise color measurement and quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries, and for fluorescent sample measurement. | |
Integrating Sphere Size | Φ40mm |
Light Source | Combined full spectrum LED light source, UV light source |
Spectrophotometric Mode | Flat Grating |
Senso | Silicon photodiode array (double row 40 groups) |
Wavelength Range | 400~700nm |
Wavelength Interval | 10nm |
Semiband Width | 10nm |
Measured Reflectance Range | 0-200% |
Measuring Aperture | MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm |
Specular Component | SCI&SCE |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 Munsell(C/2) |
Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
Other Colorimetric Index | WI(ASTM E313,CIE/ISO,AATCC,Hunter), |
YI(ASTM D1925,ASTM 313), | |
Metamerism Index MI, | |
Staining Fastness, Color Fastness, Color Strength, Opacity, | |
8° Glossiness,555 tone classification | |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measuring Time | About 1.5s (Measure SCI & SCE about 3.2s) |
Repeatability | Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%) |
Chromaticity value: MAV/SCI, within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Inter-instrument Error | MAV/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles) |
Measurement Mode | Single Measurement, Average Measurement(2-99times) |
Locating Method | Camera Locating,stabilizer cross position |
Dimension | L*W*H=129X76X217mm |
Weight | Approx 600g |
Battery | Li-ion battery, 6000 measurements within 8 hours |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Displayed Data | 3.5-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB, Bluetooth 4.2 |
Data Storage | Standard 1000 Pcs, Sample 30000 Pcs |
Language | Simplified Chinese, English, traditional Chinese |
Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
Storage Environment | -20~50℃, 0~85%RH (no condensing) |
Standard Accessory | Power Adapter, User Guide, PC Software(Download from office website), USB cable, White and Black Calibration Cavity, Protective Cover, Wrist strap, 8mm flat aperture, 8mm tip aperture, 4mm flat aperture, 4mm tip aperture |
Optional Accessory | Micro Printer, Powder Test Box |
Notes | The specifications are subject to change without notice. |
Images:
FAQ:
1. Which models are the equivalent models to TS7700?
Answer: MINOLTA CM-700d, CM-600d are the equivalent models to 3nh TS7700.
2. Is 3nh a trader or a manufacturer?
Answer: We 3nh is a professional manufacturer, we research and develop, design and produce, market and sell color measuring instruments and gloss meters.
3. Where is your main market.
Answer: We sell to the global market.
4. Is the package strong enough to make the instrument shipped safely to customers?
Answer: Yes, of course. The instrument is packed in a firm alluminum box filled with foam.
5. Can you support OEM service?
Answer: Yes, we support OEM and ODM service.
6. How long is the warranty?
Answer: We support 1 year warranty and life-span maintenance.
7. When can you ship the goods after payment?
Answer: We have all goods in stock, and general we ship the goods within 2 working days after payment.
8. What are your main products?