3nh Spectrophotometer
-
Color Spectrophotometer
-
Colour Measurement Spectrophotometer
-
Handheld Color Spectrophotometer
-
Light Box Color Assessment Cabinet
-
Haze Meter
-
Digital Gloss Meter
-
Multi Angle Gloss Meter
-
3nh Colorimeter
-
Color Difference Meter
-
Color Matching Machine
-
Color Matching Software
-
Resolution Test Chart
-
Colour Shade Card
-
Paint Color Cards
-
Fluorescent Tube Light
-
Spectrophotometer Accessories
-
Eider GranadaThe product and the service was excelent. it came to colombia without many problems (just aduana problems)..supplier 100% recomenmed
-
Josiah HallEverything was delivered in perfect condition. After assembly, I confirmed operation. Thank you for this product.
-
Mihai PaunescuEverything went as expected and the product arrived in good condition. 3NH is a good supplier and I will definitely use them in the future.
SCI Flat Grating Portable Benchtop Spectrophotometer 3nh TS8280 FCC
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xOptical Geometry | D/8° | SCE/SCI | SCE & SCI |
---|---|---|---|
UV Light Source | Yes | Repeatibility | ΔE*≤0.03 |
Inter-instrument Agreement | ΔE*≤0.15 | Measuring Aperture | 8mm & 4mm |
High Light | SCI Portable Benchtop Spectrophotometer,Flat Grating Portable Benchtop Spectrophotometer,FCC Reflectance Color Measurement Instrument |
Shenzhen ThreeNH Technology Co., Ltd / Shenzhen Tilo Technology Co., Ltd . was found in 1998, and we are specializes in the R&D, production and sales of colorimeter, spectrophotometer, color density meter, gloss meter, color light box, color proof table, coating thickness gauge, iso test chart, etc., which is the leading producer in the color and glossy surface measurement field in China. We are also the national high technology enterprise.Till now we have received more than 20 patents and passed CE, ISO 9001, ROHS, FCC, TUV etc certifications.
Application of TS8280 portable Desktop spectrophotometer:
Model | TS8280 |
Optical Geometry | D/8(diffused illumination, 8-degree viewing angle) |
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source | |
Comply to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 | |
Characteristic | Φ30mm apertures, to adapt to the measurement of large sample; |
Rotary press type structure, more convenient for testing; | |
Accurate measurement, can be used for laboratory color accurate analysis and transmission; | |
Suitable for precise color measurement and quality control in textile and garment printing and dyeing, plastic electronics, ceramics and other industries; It can be used for fluorescence sample measurement. | |
Integrating Sphere Size | Φ152mm |
Light Source | Combined full spectrum LED light source, UV light source |
Spectrophotometric Mode | Flat Grating |
Senso | Silicon photodiode array (double row 40 groups) |
Wavelength Range | 400~700nm |
Wavelength Interval | 10nm |
Semiband Width | 10nm |
Measured Reflectance Range | 0~200% |
Measuring Aperture | Φ30mm/Φ25.4mm |
Specular Component | SCI/SCE |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 Munsell(C/2) |
Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
Other Colorimetric Index | WI(ASTM E313,CIE/ISO,AATCC,Hunter), |
YI(ASTM D1925,ASTM 313), | |
Metamerism Index MI, | |
Staining Fastness, Color Fastness, Color Strength, Opacity | |
8° Glossiness,555 tone classification | |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Simulation, Color Offset |
Measuring Time | About 1.5s (Measure SCI & SCE about 3.2s) |
Repeatability | Chromaticity value: MAV/SCI, within ΔE*ab 0.05 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
Inter-instrument Error | MAV/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles) |
Measurement Mode | Single Measurement, Average Measurement(2-99times) |
Locating Method | Camera Locating |
Dimension | L*W*H=370X240X260mm |
Weight | About 7.8kg |
Battery | AC 24V, 3A Power adapter power supply |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | 7-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB, Bluetooth ®5.0, trigger switch interface |
Data Storage | Standard 1000 Pcs, Sample 30000 Pcs |
Language | Simplified Chinese, English, Traditional Chinese |
Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
Storage Environment | -20~50℃, 0~85%RH (no condensing) |
Standard Accessory | Power Adapter, USB Cable, User Guide, PC Software(Download from office website), White and Black Calibration Cavity,Aperture |
Optional Accessory | Micro Printer, Foot Switch, Rotating Bracket |