Handheld Silk Spectrophotometer Colour Spectrum Meter Colorimeter With 5 Apertures
Silk spectrophotometer ST70 colour spectrum meter colorimeter manufacturer from China Product Overview Handheld spectrophotometer Silk ST70 color test colorimeter spectrophotometer with 5 apertures 8mm 4mm 1*3mm Spectrophotometer ST70 is a spectrophotometer developed by Silk TS series core technology, using built-in photodiode array (double32 groups) sensors, imported whiteboard, while taking into account the measurement speed and convenience of operation. The repeatability
Interior Parts Paint Gloss Meter 1000gu PC Software YG60 For Glossy Measurement
Interior parts gloss meter digital glossmeter with 1000gu PC software for glossy measurement YG60 Technical Specification Parameters Single-angle Gloss Meter YG60 Measuring Angle 60 Comply with Standard ISO 2813, GB/T 9754, ASTM D 523, ASTM D 2457 Measuring Area 60: 9x15mm Measuring Range 60:0~1000GU Division Value 0.1GU Measurement Range Repeatability 0-100GU 100-1000GU 0.2GU 0.2%GU Measurement Standard Conform to the Working Requirements for JJG696 First Class
CE Silk YH1200 8mm Aperture d/8° portable Haze Meter
YH1200 haze meter can easily achieve ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance,haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1200 haze meter uses a PDF array detector to meet the CIE V()2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability. Technical Advantage 1.Double
8mm Aperture Silk YH1100 portable Haze Meter ASTM D1003
Introduction: YH1100 haze meter can easily achieve ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance,haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1100 haze meter uses a PDF array detector to meet the CIE V()2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability. Technical
8mm Aperture ASTM D1003 Haze Measuring Meter Silk YH1200
YH1200 haze meter can easily achieve ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance,haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1200 haze meter uses a PDF array detector to meet the CIE V()2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability. Technical Advantage 1.Double
4mm Aperture SCE SCI Haze Meter ASTM D1003 Haze Meausring Instrument YH1000
YH1000 haze meter YH1000 haze meter can easily achieve ASTM D1003 non-compensation method, full light transmittance, haze test. Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1000 haze meter uses a PDF array detector to meet the CIE V()2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability. Technical Advantage 1. Double standard
Horizontal ASTM D1003 Transmittance Glass Haze Meter Silk YH1100
Introduction: YH1100 haze meter can easily achieve ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance,haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1100 haze meter uses a PDF array detector to meet the CIE V()2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability. Technical
8mm Aperture Plastic Film Haze Meter Silk YH1000 FCC Light Transmittance Tester
Silk YH1000 ASTM D1003 Plastic Film Haze Meter/Light Transmittance Tester YH1000 haze meter can easily achieve ASTM D1003 non-compensation method, full light transmittance, haze test. Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1000 haze meter uses a PDF array detector to meet the CIE V()2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and
SCE SCI ISO 13468 Silk Haze Meter YH1200 ASTM D1003 1.5s Dynamic
Haze meter for test light transmittance Silk YH1200 with standard ASTM D1003 and ISO 13468 YH1200 haze meter can easily achieve ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance,haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1200 haze meter uses a PDF array detector to meet the CIE V()2 degree visual response. The compensation method can be used to measure the light
YH1200 8mm Aperture Silk Haze Meter Full Light Transmittance For Plastic Glass
YH1200 haze meter can easily achieve ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance,haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1200 haze meter uses a PDF array detector to meet the CIE V()2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability. Technical Advantage 1.Double
Flat Grating Handheld Spectrophotometer Paint Color Test Equipment Silk TS7600 D/8
Product Description Specification Model TS7700 Optical Geometry Reflect: di:8, de:8(diffused illumination, 8-degree viewing angle) SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 Characteristic double apertures for accurate color analysis and transmission in laboratory It is used for precise color measurement and quality control
Color Spectrum Analyzer Silk Spectrophotometer TS7700 With Pantone Paint Color Mixing Software
Product Description Specification Model TS7700 Optical Geometry Reflect: di:8, de:8(diffused illumination, 8-degree viewing angle) SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 Characteristic double apertures for accurate color analysis and transmission in laboratory It is used for precise color measurement and quality control