3nh Spectrophotometer
-
Color Spectrophotometer
-
Colour Measurement Spectrophotometer
-
Handheld Color Spectrophotometer
-
Light Box Color Assessment Cabinet
-
Haze Meter
-
Digital Gloss Meter
-
Multi Angle Gloss Meter
-
3nh Colorimeter
-
Color Difference Meter
-
Color Matching Machine
-
Color Matching Software
-
Resolution Test Chart
-
Colour Shade Card
-
Paint Color Cards
-
Fluorescent Tube Light
-
Spectrophotometer Accessories
-
Eider GranadaThe product and the service was excelent. it came to colombia without many problems (just aduana problems)..supplier 100% recomenmed
-
Josiah HallEverything was delivered in perfect condition. After assembly, I confirmed operation. Thank you for this product.
-
Mihai PaunescuEverything went as expected and the product arrived in good condition. 3NH is a good supplier and I will definitely use them in the future.
Liquid Powder Coffee Hunter Lab Colorimeter NH310 3nh With Universal Test Componets Accessory

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xOptical Geometry | 8°/d | Measuring Aperture | Φ8mm & Φ4mm |
---|---|---|---|
Repeatibility | ΔE*≤0.06 | Inter-instrument Agreement | ΔE*≤0.4 |
Data Port | USB | Storage Capacity | 100 Standards & 2000 Samples |
High Light | portable spectrophotometer colorimeter,digital color meter,Liquid Powder Coffee Colorimeter |
Liquid powder coffee colorimeter cheap color meter NH310 3nh with universal test componets accessory
Information:
NH310 high-quality portable colorimeter has adopted multi-channel color sensors of international brands, more stable IC platform as well as efficient and accurate algorithms to provide users with accurate and fast color management and application. NH310 is also designed with ergonomics and humanized operation and it has applied for a number of patents. NH310 is a multifunctional colorimeter with high quality and competitive price. 3nh insists on independent research whose technology innovation is unique in color management field. NH310 is the most convenient colorimeter for users.
Potents:
No.1 Camera locating and illumination location (NH310 has new functions of double locating.)
No. 2 Built-in white plate; Automatic calibration at startup (for NH310)
No. 3 Extended aperture (optional), available for measuring concave surface
Application:
NH310 colorimeter has many functions which can measure color fastness, whiteness (Hunter and ISO R457), Yellowness (YI), etc. However, we can also customize the following light sources for customers. It's used to compare color difference in plastic, electronic, painting, coating, ink, texile, garment, printing, dyeing, food, medical, cosmetic industries and institutes, schools and laboratoris.
Specification:
Model | NH310 Colorimeter |
Illuminating/Viewing Geometry | 8/d |
Measuring Aperture | Φ8mm/Φ4mm |
Detector | Silicon photoelectric diode |
Color Space |
CIEL*a*b*C*h* CIEL*a*b* CIEXYZ CIERGB CIEL*u*v* CIEL*C*h Yellowness & Whiteness Color Fastness |
Color Difference Formula | ΔE*ab ΔL*a*b ΔE*C*hΔECIE94 |
Light Source | D65 D50 A |
Light Source Device | LED blue light excitation |
Errors Between Each Equipment | ≤0.40ΔE*ab |
Storage | 100pcs standards 20000pcs samples |
Repeatability |
Standard deviation within ΔE*ab 0.06 Average of 30 measurements of standard white plate |
Weight | 500g |
Dimension | 205×70×100 mm |
Power source | Rechargeable lithium-ion battery 3.7V@3200mAh |
Lamp Life | 5 years, more than 1.6 million measurements |
Charging Time | 2 hours (first time 8 hours--100% electricity) |
Measurement Times Before Recharging | More than 3000 times |
Operating Temperature/Humidity Range | -10~40℃, relative humidity 0~85% with no condensation |
Data Interface | USB |
Extended Aperture (optional) | Φ8mm extended aperture, available for measuring concave surface |
Printer (optional) | Miniature thermal printer |
Images:
Company:
Shenzhen 3nh Technology Co., Ltd. is a high-tech enterprise. We research, develop, produce and market photoelectric detection products in photoelectric detection technology field and color management field.After years of intensice research, 3nh has launched YS series spectrophotometer, NS series spectrophotometer and NH, NR series colorimeter, ISO12233 resolution test chart, optical image test solution and specific standard illuminant which are widely used in plastic, electronic, paint, ink, textile, garment, printing and dyeing, food, medical, cosmetic, optical image test industries and the field of scientific research, school and laboratory. Our products are exported around the world. We can provide customization service which has been well received by customers.
FAQ:
1. When I received NH310/NH300 colorimeter and perform measurement, why the measured data is abnormal?
After receiving NH310/NH300, you have to perform white and black calibration manually when first starting.
2. In which condition, manual white and black calibration and auto calibration are required for NH310?
a. It’s needed to perform manual calibration for NH310 when first starting.
b. In the subsequent starting, NH310 will perform auto calibration at startup. No need to perform manual calibration.
c. Suggestion: it’s best to perform manual calibration once a week or when NH310 measured data is not accurate.
3. In which condition, manual white and black calibration for NH300 is required?
a. It’s needed to perform manual calibration for NH300 when first starting.
b. In the subsequent starting, no need to perform manual calibration.
c. Suggestion: it’s best to perform manual calibration once a week or when NH300 measured data is not accurate.
4. How to replace NH310 measuring aperture?
There are three measuring apertures for NH310: Φ8mm (standard accessory), Φ4mm (standard accessory), extended Φ8mm (optional accessory)
a. Turning on
b. Removing measuring aperture, install the needed measuring aperture.
c. Select “Settings-Aperture Setting” in main menu to select corresponding measuring aperture.
d. After selecting aperture, the instrument will display “White and Black Calibration” interface. White and black calibration must be performed.
e. Replace completed.
5. CQCS3 (Color Quality Control System) Installation
a. Before installation, please Copy CQCS3 folder to your computer and don’t remove any files in CQCS3 folder.
b. Double-click the setup.exe to install CQCS3 software.
c. Then double-click Install.bat under the CQCS3USB_Driver file to install the driver.
d. Detailed installation information please read the "Installing Software" under CQCS3 User manual.doc.
Warranty:
NH310 color reader colorimeter for liquid powder coffee colour check with accessory is under warranty for 12 months from the purchase date. Customers must provide warranty card and valid proof of purchase.